Skip to content
Aerocel™HYYTRADE · BEIJING

01 / CORE TECHNOLOGY — 50% OF OUR BUSINESS

Aerospace-grade insulation, engineered not to collapse.

A sealed micro-nano closed-cell polymer matrix — 0.015 W/(m·K), zero powder shedding, with a material-level physical limit of -60°C to 150°C. Developed for extreme-cold gear, battery thermal barriers and smart building textiles.

Developed by Powder Technology Research Laboratory, Beihang University | Officially Commercialized by Hongyuyao

Registered Vendor on the United Nations Global Marketplace (UNGM Vendor ID: #1283160)

Third-party reports were commissioned and produced by the Beihang University powder technology laboratory; Hongyuyao is the officially appointed promotion entity for Aerocel™.

0.015 W/(m·K) Thermal conductivity — about 44% below still air
Zero Powder shedding 100% shedding-free sealed-cell polymer matrix
50kg/cm² Sustained load No structural collapse, good recovery
-60 ~ 150°C Material-level limit -60°C to 150°C material-level physical limit; finished-product range depends on construction

Source: Aerocel™ Technical Data Sheet HY-AEROCEL-TDS-001 V1.1 (Nov 2026), Beihang Key Laboratory measurements.

02 / DATA & BENCHMARK GRID

Measured against the materials you are using now.

Aerocel™ figures come from Technical Data Sheet HY-AEROCEL-TDS-001 V1.1. Competitor figures are industry benchmark ranges compiled in our 2026-10-28 internal comparison sheet — not third-party results on identical specimens.

Thermal conductivity · W/(m·K) — lower is better

0 ───────────── 0.070
  • Aerocel™ 0.015
  • 800FP goose down 0.024–0.035
  • Primaloft / 3M 0.030–0.040
  • Conventional aerogel blanket No verified data

Bar length = upper bound of the published range, scaled to 0.070 W/(m·K). Conventional aerogel blanket is intentionally left blank: no physical test data exists in the current source set.

Swipe horizontally to compare on mobile

Aerocel versus benchmark insulation materials
Dimension Aerocel™ Aerogel blanket 800FP goose down Primaloft / 3M synthetic
Thermal conductivityW/(m·K) 0.0150.0136–0.015, ~44% below still air Pending verification 0.024 – 0.035 0.030 – 0.040
Powder sheddingqualitative Zero100% sealed-cell matrix; rub-tested Pending verification Down / feather migration Fibre migration
Compression / thickness retentionqualitative 50 kg/cm²Sustained load, no collapse, good recovery Pending verification Collapses under body load; insulation lost 20–30% insulation loss under pressure
Laundry decayinsulation loss <5% / <10%After 10 / 50 standard machine washes Pending verification Clumping, fill migration, hard to dry Fibre shift after repeated washes
Thickness-to-weightloft equivalence 4 mm = 15 mm down45 – 60 g/m² Pending verification 15 mm loft baseline 10–12 mm ≈ 15 mm down

Sources: HY-AEROCEL-TDS-001 V1.1 (Beihang Key Laboratory measurements; SGS NGBEC26005076901 / 6902; Guangdong Institute of Microbiology 2026FM12672R01; CTTC BA26000414); internal 2026-10-28 'Textile Insulation Materials vs Aerocel' benchmark sheet, sheet 'Performance & Process Benchmark'.

No unified third-party thickness-retention or shedding-rate percentages exist for the comparator materials; those rows are qualitative only. Metrics not listed in the TDS are not warranted. CTTC BA26000414 publishes measured values only and is not a pass/fail certificate.

Verified lab demonstrations

150°C

Hot-plate / ice test

A 0.8 mm Aerocel™ sheet on a 150°C hot plate: ice placed on top does not melt.

BP Home Textiles & Building V1.0
H₂O

Boiling vapour transmission

Steam from boiling water passes through in seconds; natural moisture release, no stuffiness.

TDS V1.1 §2.2 · BP Apparel V2.0
-35°C

Dynamic low-temperature flex

Structure stable from -35°C deep chill through 110–150°C hot-plate testing; no embrittlement under dynamic flex.

BP Industrial Thermal V2.0

Compliance & test reports

253 + 1 SVHC screenedAll ≤0.1% · SGS NGBEC26005076901 (EN) / 6902 (CN)
VeganNo asbestos, heavy metals or toxic plasticisers · SGS
AntimicrobialS. aureus 99%, E. coli 97% · 2026FM12672R01

Flame behaviour is self-extinguishing with no melt dripping at material level; no third-party GB 8624 B1 / EN 13501-1 / UL 94 classification has been obtained. CTTC BA26000414 is a commissioned test with a '—' verdict field, measured values only.

03 / APPLICATION SOLUTIONS

Three places Aerocel™ changes the specification.

A

Alpine & Outdoor Gear

Extreme-cold sleeping bags & one-piece down suits

Compression-proof cold-bridge control for shoulders, back panels and knees. A continuous sheet removes double down-proof liner fabric and box-wall filling labour — lighter build, no down migration.

4 mm = 15 mm down · 50 kg/cm²
B

BESS & Clean Energy

C&I storage and EV battery thermal-runaway barriers

Dust-free die-cutting and CNC cutting keep assembly lines clean. Edges do not shed or fray; the closed-cell matrix resists moisture in enclosure and cold-chain environments.

Zero shedding · -60°C to 150°C (material level)
C

Smart Architectural & Home Textiles

Premium curtains, solar shades & anti-condensation wall linings

Ultra-thin liners add thermal resistance without bulk, allow rapid vapour transmission, and inhibit microbial growth in humid interiors.

0.50–0.85 mm · 45–60 g/m²

04 / THE OTHER TWO WINGS — 5 : 3 : 2

A focused group, not a catalogue.

Aerocel™ leads at 50% of the business. Two further divisions complete the remaining 50%.

50%Aerocel™
30%Freeze-dried
12%BOT-WTA
8%Metal fab.
D30%

Industrial Freeze-Dried Ingredients

Freeze-dried fruit & vegetable, powders and instant soup blocks

Built for large-B foodservice and food manufacturers in Europe, North America and South-East Asia. Low water activity, low fines and audited plant certifications.

  • Water activityAw < 0.20
  • Fines ratio< 3%
  • Plant certificationsBRCGS / FDA / ISO 22000
Approved core business-mix metrics · sign-off 2026-11-09.
E12% + 8%

BOT-WTA Robot & Precision Metal Fabrication

Trackless wall-climbing welding robot and CNC sheet-metal fabrication

Trackless 90° vertical wall climbing with laser seam tracking, paired with in-house CNC bending and custom stainless-steel enclosures and control consoles.

  • Wall climbing90° trackless
  • NDT pass rate> 98%
  • Materials304 / 316L
Approved core business-mix metrics · sign-off 2026-11-09.

05 / TECHNICAL DOCUMENTATION

Download the Technical Data Sheet.

Aerocel™ Technical Data Sheet HY-AEROCEL-TDS-001 V1.1 (November 2026) is published in English and Chinese. The download button follows the language currently selected on this page.

Download TDS (English) Request the third-party test report register